High Buffer utilization on FPC (Flexible PIC Concentrator) The problem related to this syslog message is described in the following sections: The RMON_EVENT_fpc_high_buffer_utilization message contains information about an FPC that has a high buffer utilization rate. An alarm is triggered when the FPC buffer utilization crosses a threshold. High FPC buffer … [Read more...]
CHASSISD_FASIC_OUTPUT_DROP
CHASSISD_FASIC_OUTPUT_DROP The message is generated by the chassis process (chassisd), which controls hardware components on the routing platform. The Packet Forwarding Engine divides packets into smaller units called cells for more efficient processing. As the indicated F chip on the indicated Control Board (CB) processed data before sending it to the indicated Packet … [Read more...]
CHASSISD_RE_OVER_TEMP_WARNING
The CHASSISD_RE_OVER_TEMP_WARNING message is reported into the system message file whenever the Routing Engine (RE) exceeds the upper temperature threshold. If the temperature does not go below the threshold within four minutes after the chassis process (chassisd) detects this condition, the chassisd process shuts down the indicated component. When this message was logged, the … [Read more...]
CHASSISD_CMB_READBACK_ERROR
The chassis process (chassisd) could not read back information from the Chassis Management Bus (CMB) about the indicated component (field-replaceable unit, or FRU). The problem related to this syslog message is described in the following sections: The CHASSISD_CMB_READBACK_ERROR message is logged when the chassisd process is not able to read information from the component … [Read more...]
High CPU occurs in all FPC when datapath debug is enabled
On an SRX1K/3K, despite CPU in both SPU and RE is low, High CPU in 'show chassis fpc' is observed when datapath debug is enabled. On an SRX1K/3K device, low CPU is seen in both SPU and RE. However, when datapath debug is enabled, the CPU in ‘show chassis fpc’ is high. In the following example, 100% CPU is seen in all FPC: Note: Slot 7 and 8 is SPC SRX3600.HK> show … [Read more...]
Linecards of an EX9200 switch are showing in present state after removing MC-LAG configuration
This article describes the issue when trying to recover linecards after removing MC-LAG configuration that are showing in “present “ state and how to fix it. Virtual chassis and MC-Lag cannot co-exist together on the same chassis causing the linecards go in present state throwing these errors in chassisd: Feb 23 23:49:58 SCC: lcc_detach_interfaces_not_online lcc 0 Feb 23 … [Read more...]
RMON_EVENT_fpc_high_heap_utilization
RMON_EVENT_fpc_high_heap_utilization The problem related to this syslog message is described in the following sections: The RMON_EVENT_fpc_high_heap_utilization message contains information about a FPC that is experiencing high memory utilization. An alarm is triggered when the heap utilization crosses a threshold. The message logged will look similar to … [Read more...]
CHASSISD_VOLTAGE_READ_FAILED
The CHASSISD_VOLTAGE_READ_FAILED message is reported into the system message file whenever the chassis control process (chassisd) is not able to read voltage data from a Field Replaceable Unit (FRU). This article documents an approach to troubleshoot this problem. The problem related to this syslog message is described in the following sections: The … [Read more...]
CHASSISD_FASIC_INPUT_DROP
CHASSISD_FASIC_INPUT_DROP The Packet Forwarding Engine divides packets into smaller units, known as cells, for more efficient processing. As the indicated F-chip on the indicated Control Board (CB) processed data, which was received from the indicated Packet Forwarding Engine (PFE) on the indicated Flexible PIC Concentrator (FPC), it dropped the indicated number of cells per … [Read more...]
CHASSISD_IFDEV_DETACH_PIC
This article explains the CHASSISD_IFDEV_DETACH_PIC syslog message. The problem related to this syslog message is described in the following sections: The CHASSISD_IFDEV_DETACH_PIC message is reported in the system message file when the PIC is shut down. If the Flexible PIC Concentrator (FPC) is shut down, several of these types of messages are reported in the file, as … [Read more...]