RMON_EVENT_fpc_high_buffer_utilization

June 16, 2016 by Marques Brownlee

High Buffer utilization on FPC (Flexible PIC Concentrator) The problem related to this syslog message is described in the following sections: The RMON_EVENT_fpc_high_buffer_utilization message contains information about an FPC that has a high buffer utilization rate. An alarm is triggered when the FPC buffer utilization crosses a threshold. High FPC buffer … [Read more...]

Filed Under: Juniper Tagged With: Flexible PIC Concentrator, FPC, memory leak, PIC

CHASSISD_PIC_HWERROR

June 13, 2016 by Marques Brownlee

The message: CHASSISD_PIC_HWERROR is reported in the system message file. This article documents an approach to troubleshoot it. The message: CHASSIS_PIC_HWERROR is displayed in the syslog messages file. Following the message the FPC slot and the PIC slot in question are identified. Additional log message entries may include: RED alarms for the PIC failure and setting of … [Read more...]

Filed Under: Juniper Tagged With: chassisd, Flexible PIC Concentrator, Physical Interface Card, PIC

LIBMSPRPC_CLIENT_NO_REPLY

June 8, 2016 by Marques Brownlee

LIBMSPRPC_CLIENT_NO_REPLY Remote execution of the command given from the Routing Engine (RE) to the PIC failed. There was no reply from the PIC. This message is generated by the mspinfo process, which is responsible for RPC (Remote Procedure Call) communication between the Routing Engine and the Multiservices PICs. This only applies to M-series and T-series routers, and … [Read more...]

Filed Under: Juniper Tagged With: PIC, Remote Procedure Call, Routing Engine, RPC

How to upgrade VDSL PIC firmware

May 30, 2016 by Marques Brownlee

This article provides a step-by-step procedure for upgrading the VDSL firmware via the CLI. Perform the following steps to upgrade the firmware: Step 1: Check the current firmware version of VDSL PIC. [email protected]> show system firmware Part Type Tag Current Available Status version version FPC 1 PIC 0 VDSLBCM 10 2.10.0 OK >>>> In this case it is … [Read more...]

Filed Under: Juniper Tagged With: PIC, VDSL

CHASSISD_VOLTAGE_READ_FAILED

May 30, 2016 by Marques Brownlee

The CHASSISD_VOLTAGE_READ_FAILED message is reported into the system message file whenever the chassis control process (chassisd) is not able to read voltage data from a Field Replaceable Unit (FRU). This article documents an approach to troubleshoot this problem. The problem related to this syslog message is described in the following sections: The … [Read more...]

Filed Under: Juniper Tagged With: chassis control process, chassisd, CHASSISD_VOLTAGE_READ_FAILED, FPC, FRU, PIC

CHASSISD_IFDEV_DETACH_PIC

May 29, 2016 by Marques Brownlee

This article explains the CHASSISD_IFDEV_DETACH_PIC syslog message. The problem related to this syslog message is described in the following sections: The CHASSISD_IFDEV_DETACH_PIC message is reported in the system message file when the PIC is shut down. If the Flexible PIC Concentrator (FPC) is shut down, several of these types of messages are reported in the file, as … [Read more...]

Filed Under: Juniper Tagged With: chassisd, CHASSISD_IFDEV_DETACH_PIC, FPC, Physical Interface Card, PIC

KMD_INTERNAL_ERROR: kmd_pic_connect_failure_cb: Failed to connect PIC

May 28, 2016 by James Palmer

Kernel Management Daemon (KMD) Internal Error during an interface connection failure. Example of the kmd.core that was generated Log Messages: Aug 18 09:38:16 XXXXXXX-xxxx-1 init: ipsec-key-management (PID 3633) terminated by signal number 11. Core dumped! Aug 18 09:38:16 XXXXXXX-xxxx-1 /kernel: tcp_auth_ok: Packet from 10.254.2.14:38567 unexpectedly has MD5 digest Aug 18 … [Read more...]

Filed Under: Juniper Tagged With: chassisd, KMD, KMD_INTERNAL_ERROR, kmd_pic_connect_failure_cb, PIC

CHASSISD_ISSU_ERROR

May 26, 2016 by Marques Brownlee

The chassisd process (chassisd) encountered an error during the In Service Software Upgrade (ISSU) Process. When a CHASSISD_ISSU_ERROR event occurs, a message similar to the following is reported: chassisd[1179]: CHASSISD_ISSU_ERROR: Daemon ISSU Abort -1(NSR sync not complete: PIM) chassisd[6511]: CHASSISD_ISSU_ERROR: Daemon ISSU Abort -1(chassisd … [Read more...]

Filed Under: Juniper Tagged With: chassisd, CHASSISD_ISSU_ERROR, Flexible PIC Concentrator, FPC, ISSU, NSR, PIC

Recent Posts

  • How do I give user access to Jenkins?
  • What is docker volume command?
  • What is the date format in Unix?
  • What is the difference between ARG and ENV Docker?
  • What is rsync command Linux?
  • How to Add Music to Snapchat 2021 Android? | How to Search, Add, Share Songs on Snapchat Story?
  • How to Enable Snapchat Notifications for Android & iPhone? | Steps to Turn on Snapchat Bitmoji Notification
  • Easy Methods to Fix Snapchat Camera Not Working Black Screen Issue | Reasons & Troubleshooting Tips to Solve Snapchat Camera Problems
  • Detailed Procedure for How to Update Snapchat on iOS 14 for Free
  • What is Snapchat Spotlight Feature? How to Make a Spotlight on Snapchat?
  • Snapchat Hack Tutorial 2021: Can I hack a Snapchat Account without them knowing?

Copyright © 2023 · News Pro Theme on Genesis Framework · WordPress · Log in