High Buffer utilization on FPC (Flexible PIC Concentrator) The problem related to this syslog message is described in the following sections: The RMON_EVENT_fpc_high_buffer_utilization message contains information about an FPC that has a high buffer utilization rate. An alarm is triggered when the FPC buffer utilization crosses a threshold. High FPC buffer … [Read more...]
CHASSISD_PIC_HWERROR
The message: CHASSISD_PIC_HWERROR is reported in the system message file. This article documents an approach to troubleshoot it. The message: CHASSIS_PIC_HWERROR is displayed in the syslog messages file. Following the message the FPC slot and the PIC slot in question are identified. Additional log message entries may include: RED alarms for the PIC failure and setting of … [Read more...]
LIBMSPRPC_CLIENT_NO_REPLY
LIBMSPRPC_CLIENT_NO_REPLY Remote execution of the command given from the Routing Engine (RE) to the PIC failed. There was no reply from the PIC. This message is generated by the mspinfo process, which is responsible for RPC (Remote Procedure Call) communication between the Routing Engine and the Multiservices PICs. This only applies to M-series and T-series routers, and … [Read more...]
How to upgrade VDSL PIC firmware
This article provides a step-by-step procedure for upgrading the VDSL firmware via the CLI. Perform the following steps to upgrade the firmware: Step 1: Check the current firmware version of VDSL PIC. user@host> show system firmware Part Type Tag Current Available Status version version FPC 1 PIC 0 VDSLBCM 10 2.10.0 OK >>>> In this case it is … [Read more...]
CHASSISD_VOLTAGE_READ_FAILED
The CHASSISD_VOLTAGE_READ_FAILED message is reported into the system message file whenever the chassis control process (chassisd) is not able to read voltage data from a Field Replaceable Unit (FRU). This article documents an approach to troubleshoot this problem. The problem related to this syslog message is described in the following sections: The … [Read more...]
CHASSISD_IFDEV_DETACH_PIC
This article explains the CHASSISD_IFDEV_DETACH_PIC syslog message. The problem related to this syslog message is described in the following sections: The CHASSISD_IFDEV_DETACH_PIC message is reported in the system message file when the PIC is shut down. If the Flexible PIC Concentrator (FPC) is shut down, several of these types of messages are reported in the file, as … [Read more...]
KMD_INTERNAL_ERROR: kmd_pic_connect_failure_cb: Failed to connect PIC
Kernel Management Daemon (KMD) Internal Error during an interface connection failure. Example of the kmd.core that was generated Log Messages: Aug 18 09:38:16 XXXXXXX-xxxx-1 init: ipsec-key-management (PID 3633) terminated by signal number 11. Core dumped! Aug 18 09:38:16 XXXXXXX-xxxx-1 /kernel: tcp_auth_ok: Packet from 10.254.2.14:38567 unexpectedly has MD5 digest Aug 18 … [Read more...]
CHASSISD_ISSU_ERROR
The chassisd process (chassisd) encountered an error during the In Service Software Upgrade (ISSU) Process. When a CHASSISD_ISSU_ERROR event occurs, a message similar to the following is reported: chassisd[1179]: CHASSISD_ISSU_ERROR: Daemon ISSU Abort -1(NSR sync not complete: PIM) chassisd[6511]: CHASSISD_ISSU_ERROR: Daemon ISSU Abort -1(chassisd … [Read more...]