A read() operation failed at the indicated address on the system management bus (SMB). The problem related to this syslog message is described in the following sections: An error similar to the following is reported: CHASSISD_SMB_READ_FAILURE: <function-name>: read() failed on system management bus (address 0x<memory-address>) This error may indicate a … [Read more...]
CONNECTION_CHASSISD_FAIL
CONNECTION_CHASSISD_FAIL The alarm process (alarmd) was unable to connect to the chassis process (chassisd). The problem related to this syslog message is described in the following sections: The CONNECTION_CHASSISD_FAIL is logged every 30 failed attempts by the alarm process to connect to the chassis process. When a CONNECTION_CHASSISD_FAIL event occurs, a syslog … [Read more...]
CHASSISD_RE_OVER_TEMP_CONDITION
The CHASSISD_RE_OVER_TEMP_CONDITION message is reported into the system message file whenever the Routing Engine temperature exceeds the upper threshold. This article documents an approach to troubleshoot this problem. The CHASSISD_RE_OVER_TEMP_CONDITION message is logged each time the Routing Engine temperature exceeds the designated upper threshold. When a … [Read more...]
CHASSISD_OVER_TEMP_SHUTDOWN_TIME
The chassis process (chassisd), which controls hardware components on the routing platform, shut down the routing platform because the temperature of one or more components exceeded the indicated threshold temperature for the indicated amount of time. Continued operation at the excessive temperature could damage the routing platform. The CHASSISD_OVER_TEMP_SHUTDOWN_TIME … [Read more...]
CHASSISD_VOLTAGE_READ_FAILED
The CHASSISD_VOLTAGE_READ_FAILED message is reported into the system message file whenever the chassis control process (chassisd) is not able to read voltage data from a Field Replaceable Unit (FRU). This article documents an approach to troubleshoot this problem. The problem related to this syslog message is described in the following sections: The … [Read more...]
CHASSISD_IFDEV_DETACH_PIC
This article explains the CHASSISD_IFDEV_DETACH_PIC syslog message. The problem related to this syslog message is described in the following sections: The CHASSISD_IFDEV_DETACH_PIC message is reported in the system message file when the PIC is shut down. If the Flexible PIC Concentrator (FPC) is shut down, several of these types of messages are reported in the file, as … [Read more...]
KMD_INTERNAL_ERROR: kmd_pic_connect_failure_cb: Failed to connect PIC
Kernel Management Daemon (KMD) Internal Error during an interface connection failure. Example of the kmd.core that was generated Log Messages: Aug 18 09:38:16 XXXXXXX-xxxx-1 init: ipsec-key-management (PID 3633) terminated by signal number 11. Core dumped! Aug 18 09:38:16 XXXXXXX-xxxx-1 /kernel: tcp_auth_ok: Packet from 10.254.2.14:38567 unexpectedly has MD5 digest Aug 18 … [Read more...]
CHASSISD_ISSU_ERROR
The chassisd process (chassisd) encountered an error during the In Service Software Upgrade (ISSU) Process. When a CHASSISD_ISSU_ERROR event occurs, a message similar to the following is reported: chassisd[1179]: CHASSISD_ISSU_ERROR: Daemon ISSU Abort -1(NSR sync not complete: PIM) chassisd[6511]: CHASSISD_ISSU_ERROR: Daemon ISSU Abort -1(chassisd … [Read more...]
CHASSISD_FASIC_PIO_READ_ERROR
The CHASSISD_FASIC_PIO_READ_ERROR message is reported into the system message file whenever a read error is detected by the chassisd process on a fabric link. The problem related to this syslog message is described in the following sections: The CHASSISD_FASIC_PIO_READ_ERROR message is logged whenever a read error is detected by the chassisd process on a fabric … [Read more...]
CHASSISD_FAN_FAILURE
This message usually means that you need to replace the specified fan. The CHASSISD_FAN_FAILURE message is logged each time a fan failure is detected. The chassisd process will raise an alarm and increase the speed of the remaining fans to full speed. The alarm you will see should look similar to this: CHASSISD_FAN_FAILURE: SRX220 Chassis fan 0 in slot 0 failed This … [Read more...]