This article describes the issue of the PSU Fan Failed messages being generated in the system log (syslog) on the EX8200 Virtual Chassis; even though the PSU fan is working normally.

PSU Fan Failed messages are generated in the system log (syslog) on the EX8200 Virtual Chassis; even though the PSU fan is working normally.

On the EX8200 Virtual Chassis, PSU Fan failed messages are generated in the syslog; even though the PSU Fan is working normally.
For example:

These alarms are false alarms and are short duration events, due to a software issue.

  • PSU Fan Failed alarms are continuously generated and cleared after 5 seconds in syslog.
  • Check the LEDs on the PSU. Green LEDs indicate that the PSU is operational.

This issue has been fixed in Junos 11.4R6, 12.3R1, 12.2R2, 11.4R5-S2, and 12.1R5.