An internal consistency check failed due to a mismatch between expected and received values for the specified object. This is relevant only to GGSN (Gateway GPRS Support Node), and only applies to M, MX and T series routers.
The SERVICED_INTERNAL_INCONSISTENCY message is logged each time the Services PICs process (serviced) detects a mismatch between a value that was received from an object, and the value that was expected from that same object.
When a SERVICED_INTERNAL_INCONSISTENCY event occurs, a message similar to the following is reported:
serviced: SERVICED_INTERNAL_INCONSISTENCY: <function-name>: failure <object-name>: <reason>
The cause of the SERVICED_INTERNAL_INCONSISTENCY event is due to an internal software failure occurring.
Examine the following output to help determine the cause of this message:
show log messages show log serviced show system core-dumps
Look for any related events that occurred at or just before the SERVICED_INTERNAL_INCONSISTENCY message.